The platform is a loose federation of already existing testbed owned and operated by distinct organizations for purposes of research and development. Fike twinflex pro 2wire fire alarm panels fike fire. The twinflexpro system has the ability to set a prealarm for dwellings, allowing time to investigate the cause of the activation before evacuating the building. Instead, it connects to a control panel and reports events which occur on the control panel. Fike s fmapproved technology detects visible flames, reflected flames, pluming smoke clouds, ambient smoke and even oil mist. Software version this active control will allow the engineer to view the version of panel 010909 20. When used with the twinflex pro panel, the outputs will only come on in a fire condition. Quick shop 202 0001 twinflex multipoint detector with sounder. Fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. A conventional 2wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist. Acorn fire and security one of the uks leading fire alarm equipment.
Twinflexpro osp, pc programming software requires usb a to usb b lead, not supplied fc3039. It does not connect to or control detection devices. Clink supports virtually every test system on the market. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. Available from fire protection shop are a range of fike twinflex pro fire alarm. Gb2370670, ep1158472, gb2346758, ep0917121, gb2329056, pt1035528t, ep0980056. Twinflexpro control panel engineering and commissioning manual 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Founded in 1945 and headquartered in blue springs, missouri, usa, fike has grown to become a globally recognized supplier doing business with.
The twinflexpro two wire fire alarm system incorporating the multipoint asd combined smoke and heat detector with optional builtin sounder and strobe, allows the whole system to be easily installed using only one pair of wires per zone. The system is classed as analogue nonaddressable due to the architecture used within the design. When used with a twinflex v3 panel, the outputs will come on when the sounders are on. Fike fire detection products acorn fire and security. Freephone 0800 999 2661 phone 0330 058 0630 cart is empty.
The innovative technology built into the duonet and quadnet panels is designed to significantly reduce false alarms. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. For more information on the rafiki twinflex two wire fire alarm system call us now on 01200 428 410. Twinflexpro osp, pc programming software requires usb a. Duonet panels panels fike managed protocol systems. The companies have to spend more money for their legal department, to register patents, to negotiate patent crosslicensing, and to defend themselves against patent claims.
Vision to eliminate catastrophic loss of life and assets for companies around the world. Weve developed several important resources to assist you in. This versatile fike twinflex 5050004 fire alarm panel incorporates fikes multipoint detection system using smoke and heat detectors with builtin sounder, allowing the whole system to be installed using. The checking period can be between 1 5 minutes and is selected at commissioning stage upon. Due to the complexity and inherent importance of a system covering a life protection risk, training on. Twinflex pro control panel user guide 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Software piracy is theft, using crack, password, serial numbers, registration codes, key generators, cd key, hacks is illegal and prevent future development of issue tracker v. This software will require usb a to usb b interface lead not supplied.
Our payment security system encrypts your information during transmission. Video detection is ideal for highceiling and open air environments, and engine rooms, diesel engines and gas turbines, where spot detectors and air sampling systems are inaccessible. Sureflex files for opening severely curved root canals have outstanding advantages over traditional stainless steel instruments. File sharing and data security solutions for hybird it fileflex. Software patents are a problem for everybody, no matter if big or small companies, individual software developers, users, nonfree or free software. Repeater panels, which are small remote display units, can be connected to a 4 or 8 zone version 2 twinflexpro panel via an rs485 data link.
Profibus dpv1 master fdt communications dtm prosoft. Also available are repeater panels, programming software, relay module. This website uses cookies to enhance your experience. Each kit contains a fike twinflex pro fire panel, 7 fike twinflex multipoint detectors with sounder, 2 fike twinflex manual call points with liftup cover and a free. Fike twinflex pro fire alarm 2 zone kit free test log book. Weve developed several important resources to assist you in learning more about our products and solutions. Twinflex pro 4 zone contractor kit 6040004 can be converted into an 8 zone with expansion card. Twinflex system installation zone planning at the planning stage, fire zones are designated as either dwelling or communal. The system is classed as analogue non addressable due to the architecture used within the design. The twinflexpro2 panel is an intelligent 2wire panel that utilises a conventional type cabling format. The twinflex 2wire and the duonetquadnet intelligent addressable systems are supported by a wide range of ancillary devices, many of which have been designed to comply with en543. The multipoint and asd detectors have set new standards in detector technology. Twinflex pro osp software requires usb a to usb b interface lead part no 505 0040. Multipoint detectors in the dwelling zones have the facility to use fikes checkpoint technology.
Fike twinflex pro 2 zone fire alarm panel, fire protection. The twinflex pro repeater panel is connected directly to the twinflex pro fire alarm panel 4 or 8 zone only and reports events which occur on the. With checkpoint alarm verification technology, the twinflex pro offers the ability to select a confirmation period for individual detectors and confirm if the smokeheat detected is an actual fire rather than a. This kit is based upon the popular fike twinflex pro range of two wire fire alarm system equipment. View and download fike gb2426367 user manual online. Fike twinflex pro 2 2, 4 or 8 zone fire alarm panel. This intelligent 2wire control panel provides 2 circuits or zones capable of holding up to 32 devices. Relay interfacing module with monitored input to provide shutodwn and monitoring facilties from the twinflex zone. Acorn fire and security one of the uks leading fire alarm equipment suppliers.
The fike 5050040 twinflex pro programming software allows simple pc based configeration of all fike twinflex pro and pro. Sounders standard internal wall and ceiling mounted as well as highoutput industrial style units. Microsoft active directory rights management services protection for pdf documents fremont, calif. Capable of running up to 64 devices in total, devices communicating with the panel do so via the twinflex data protocol. Softfire is building a federated experimental platform aimed at the construction and experimentation of services and functionalities built on top of nfv and sdn technologies. It includes drivers for both 32bit and 64bit operating systems. Fileflex enterprise is the worlds first remote data access, sharing and collaboration solution designed from the ground up to facilitate business processes effectively and efficiently with a zero trust policy engine to reduce business risk and increase productivity. Our cadcam software has since its introduction in 1985 developed into the leading standard tool. Fike twinflex pro fire alarm panels fire protection shop. The devices communicate with the control panel using the twinflex data protocol.
Twinflex pro osp software operating instructions 4 introduction twinflex pro osp is the name given to the high level software package written to enable the individual configuration of the twinflex pro fire alarm systems. The licensefree flexi soft designer configuration software enables intuitive programming, rapid commissioning, and continuous diagnostics down to the automation level. Shareware junction periodically updates pricing and software information of issue tracker v. Welcome to the sd fire alarms fike twinflex pro panel description part 1 video. Fike twinflex flashpoint low profile 302 0012 the twinflex flashpoint allows a simple and effective visual indication directly from the 2wire zone, complete with a sounder. Buy this fike fike twinflex pro 4 zone fire alarm control panel, 4 zone control panel rafiki 505 0004 5050004 online from sparks direct at our low price of. Fike 090026 spare enable key for twinflex pro, duonet and. Helping you get the most out of fike products and services is important to us. The profibus dpv1 master fdt field device tool communication dtm comdtm software is an interface between any compliant fdt software container, an fdt device dtm and applicable profibus slave devices. Installation and maintenance instructions 2020003 twinflex multipoint detector 2020001 twinflex multipoint detector with sounder 260027 issue 12 general description the multipoint is a plugin type smoke detector that utilises a photoelectric sensing chamber to make a measurement corresponding to smoke density. Activation in a communal area will initiate a full alarm immediately. This install program will install aria, sonata, and the iflex usb drivers in all versions of windows. Fike 090026 spare enable key for twinflex pro, duonet and quadnet singular singular spare or replacement enable key for the fike twinflex pro, duonet and quadnet range of fire alarm control panels.
Buy this fike fike twinflex pro osp pc programming software 5050040 online from sparks direct at our low price of. Switch off the zone at access level 3 before removing any devices or detector heads from that zone. Note that whichever panel is used, there is no difference in the mode of. Fike twinflex fire alarm 48 zone repeater tfpro8r city. We accept returns for exchange or full refund up to 14 days following delivery. This time, we have the pleasure to collaborate with one of. Clink dtm is the interface between cad, test and repair, and combines these into one platform. We would like to show you a description here but the site wont allow us.
This item is only available if traning has been carried out form to be completed before order can be sent. More products are being uploaded so if you dont find what youre looking for then drop us an email on. And our newest product, 3m tm novec tm 1230 fire protection fluid is the worlds most environmentally friendly chemical clean agent. Nov 21, 2014 features 505 0040 twinflex pro osp pc programming software ce approved. Fire protection detection and suppression solutions fike. The twinflex multipoint head is a 2wire device used with the twinflex and twinflex pro systems, whereas the addressable asd detector is used on the sita200plus, duonet and quadnet systems. To learn more about how we use cookies please take time to read our privacy statement. Fike twinflex pro 2 quick start manual pdf download. The twinflexpro2 repeater panel is smaller than the twinflexpro2 control panel. Mission fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets.
This windows based program allows the system to be set up for each application. Buy fike 5050040 twinflex pro programming software allows quick and easy programming of all twinflex pro fire alarm panels. First secure remote data access and collaboration platform for hybrid it. The twinflexpro panel monitors each zone for detector head removal, device fault, end of line fault and open or short circuit fault. The fike twinflex pro 2 zone two wire fire alarm system, is an extremely versatile fire alarm system, featuring the asd multipoint detectors. Buy fike twinflex pro fire alarm control panels, sounders, detectors and spares from stock at low trade prices, with quick shipping at. We dont currently have a summary description for this product, please contact our customer service team on 01706 658880 for more information. The fike twinflex series manual call point has set new standards in detector technology, using microprocessor control even as a conventional detector and offering the installer a full range of detection capabilities with audible warning in one compact device. Fike twinflex multipoint detector without sounder white. Profibus dpv1 master fdt communications dtm pswcdtmpdpm.
Functions to enable safe controller networking, safe series connection, or safe drive monitoring reduce costs and boost productivity. We dont share your credit card details with thirdparty sellers, and we dont sell your information to others. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of. Devices or detector heads should not be removed with the zone switched on. If you have a 64bit operating system you should select the 64bit drivers option and unselect the 32bit option. The rafiki twinflex is a two wire fire alarm system.
Fike twinflex pro enable key pair view full product details. Fike is the experienced, trusted expert in bursting disc technologies, explosion protection, fire alarm systems and fire suppression solutions. Mounted in a standard double gang box, including two sets of 2a rated spco relay contacts, one monitored input and inbuilt end of line. Fike s twinflex pro 2wire fire alarm system is known for its adaptability and costeffectiveness within a variety of applications.
The fike twinflex pro 2 zone fire alarm panel is an analogue nonaddressable panel using a conventional cabling format. Fike safety technology ltd, do not call the fike safety technology technical support 31 springvale ind est, department unless your distributor has first given their advice and cwmbran, uk. Fike 6040002 twinflex pro 2 zone 2 wire fire alarm kit. We are a dynamic, global manufacturing and services organization that provides engineered solutions for process safety and facilities protection, recognized by our customers as the industry leader consistently meeting or exceeding their requirements and expectations. Midland fire online are providers of high quality fire alarms, fire extinguishers and safety products at competitive prices. Fike twinflex pro 2, 4 or 8 zone fire alarm panel discount fire. We cannot accept items back after 14 days after delivery. Sureflex files flex to follow smoothly the curve of the root canal whether working with a very fine file or a larger size, the dentist has the same sensitive control over the cutting action. June 24, 2009 foxit corporation, a leading provider of solutions for reading, creating, organizing and securing pdf documents, announces the availability of a new white paper entitled microsoft active. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability. Fike twinflexpro2 2 zone boxed kit approved 6040002. This means that the detectors, call points, sounders and beacons can all be installed on the same radial zone circuit reducing the need to install seperate detection and sounder circuits. Each suppression system is equipped with fike s impulse valve technology, resulting in reduced friction losses, longer piperuns and greater design flexibility.
1394 616 904 1226 257 588 427 933 1492 752 376 1429 1457 1164 580 336 130 1430 582 873 938 652 1027 187 6 584 142 988 646 1054 199 969 1257